Ecodry System 4.0
Process-Synchronized Cooling
Innovation for the beer industry, thanks to an integrated cooling system designed to increase productivity, reduce operating costs and reduce the environmental impact of the entire process, from the cooling of the wort to bottling. The absence of ammonia guarantees maximum industrial safety.
Ecodry 4DK
Adiabatic Cooling System
- Up to 15% less energy consumption
- Water saving up to 95%
- Safe operation without glycol down to an ambient temperature of -30 °C (-22 ˚F)
- Remote monitoring
- Improved COP up to 30%
Maximum energy savings and ease of operation
MultiStage
Cascade refrigeration system
- Temperature and cooling flow set point synchronized with the line
- Maximum energy efficiency thanks to multi-stage cascade refrigeration
- Status of the cooling system synchronized with the line: ON, OFF, IDLE, CIP, etc.
- Can be used as a “heat pump” for energy recovery
Total process stability without interference
Industrial Chiller Medium
Air Cooled Water Chillers
- Wide product range covering all process cooling conditions and climate variations
- Maximum efficiency and reliability
- Plug-and-play, modular design for easy expansion, keeping initial installation costs to a minimum
- Latest generation microprocessor controls, providing easy service due to local recording of operating statuses, working conditions and alarm histories
Maximum process stability and efficiency
Microgel industrial Processes RVM
Water condensed refrigeration unit
- Temperature and cooling flow set point synchronized with the line
- Status of the cooling system synchronized with the line: ON, OFF, IDLE, CIP, etc.
- Can be used as a heat pump for energy recovery
High energy savings with precise control
Microgel Injection Molding RSD
Revolutionary Temperature Control Unit with Chiller
- Control of the mold temperature synchronized with the process
- Increased production up to 50% thanks to the drastic reduction of cooling time
- Intelligent use of energy consumption
- Affordable investment & high ROI
- It does not require modifications to the mold
Download the brochure of the cooling system Beer
Performance and sustainability without compromise
Reduced carbon footprint up to 50% less
Unbeatable efficiency, free-cooling and heat recovery opportunities.
Increased productivity
1. Maximum flexibility
There is no limitation for settings of coolant temperature and flow rate delivered to each process. The operator is able to record the cooling parameters that maximize the processing line speed for each specific product.
2. Perfect stability
Each unit assures precise temperature control and constant flow rate of coolant to each process with complete independence - avoiding interference from the demands of other processes.
3. Full automation and connectivity
Each cooling Unit is automatically operated by the processing line and is constantly communicating with it, reducing ramp-up times and any dead time during production stops, change of formats, change of product, etc.
4. High reliability
All Ecodry Sytem components are factory assembled and pre-tested before shipping. MultiStage units are typiclly designed with one back-up stage, all easily replaceable in case of failure.
Reduced operating costs
1. Energy savings up to 30%
• Maximum overall system efficiency (EER/COP) - Each refrigeration unit operates at a specific temperature, guaranteeing the highest level of efficiency for each refrigeration circuit for each process.
• Maximum operational efficiency of each unit (EER/COP) - Each process with a high temperature differential is associated with a MultiStage cascade refrigeration system equipped with compressors and pumps with inverters.
• Optional Free-Cooling - The refrigeration units integrate the automatic Free-Cooling function. Whenever the temperature required by the process is higher than the temperature provided by the central system, the refrigeration compressors are unloaded or stopped.
• Heat recovery option - The units can be used as heat pumps for water heating by recovering up to 100% of the heat taken from the refrigeration loads.
2. Water savings up to 95%
The Central Adiabatic Cooling system operates in dry mode without water consumption for almost the whole year, exploiting the ambient air to reject the heat coming from the processes. Only during extreme heat periods above 30 ˚C (86 ˚F) does the system uses a minimum amount of water in evaporative mode.
3. Maintenance and industrial security savings up to 90%
Refrigeration units require simple maintenance and they operate with harmless gases that do not require specific safety infrastructures. In addition, the central adiabatic system is a closed circuit requiring minimum maintenance.
Total modularity
1. Easily expandable at any time
The Ecodry System allows the installation of the exact capacity required at each stage of plant development.
2. Exact quantification of cooling costs by line and product
Each unit can measure and record the specific energy consumption for each product.
3. Total reliability
The extreme simplicity, reliability and redundancy of the components of the adiabatic cooling unit minimizes the possibility of plant shutdown due to failures of the cooling system, ensuring the continuity of production 24 hours a day.
Reduced carbon footprint up to 50% less
1. Intelligent electricity consumption
With minimal waste.
2. Maximum savings
Obtained thanks to automatic and independent Free-Cooling by process.
3. Possibility of reducing the consumption of natural gas
Thanks to the heat recovery of processes through heat pumps.
Almost no water footprint
Unlike traditional systems, this new heat dissipation technology minimizes water consumption caused by refrigeration systems that provide direct evaporation to reduce temperatures.
Lowest risks of emissions
1. Free of ammonia
Unlike traditional systems, the system ensures the total absence of ammonia.
2. Low GWP refrigerant
The system uses a refrigerant gas with the lowest GWP available to date.
3. Risk of losses and emissions reduced to a minimum
In each unit the refrigerant gas is divided into small separate circuits, minimizing the risk of emissions in the event of leaks or leaks.
4. No disposal of chemical additives
It does not require the disposal of chemical additives used for water treatment.
Other solutions for Beer
Discover our alternatives
High performance for every process need.